Programmable Output
e SWM24SF and SWM24QF include four “ex I/O” points which can be individually congured to act as digital out-
puts. e SWM24Q, SWM24S and SWM24IP includes one dedicated digital output. Each output can be set to auto-
matically control a motor brake, to signal a fault condition, to indicate when the motor is moving or to provide an output
frequency proportional to motor speed (tach signal). An output can also be turned on and o by program instructions
like Set Output. An output can be used to drive LEDs, relays and the inputs of other electronic devices like PLCs and
counters. e “OUT+” (collector) and “OUT-” (emier) terminals of the transistor are available at the connector. is al-
lows you to congure the output for current sourcing or sinking.
Diagrams of various connection types follow.
Do not connect the output to more than 30VDC.
e current through the output terminal must not exceed 40ma.
Connecting a Sinking Output
Connecting a Sourcing Output
5-24 VDC
Power Supply
+
Load
SWM24
OUT+
OUT
-
5-24 VDC
Power Supply
+
Load
SWM24
OUT+
OUT
-
26