Alarm Codes
In the event of a drive fault or alarm, the green LED will ash one or two times, followed by a series of red ashes. e pat-
tern repeats until the alarm is cleared.
404 Westridge Drive Watsonville, CA 95076
Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544
www.applied-motion.com
Power and Motor Connector Signal Connector
Connector Diagrams
Code Error
solid green no alarm, motor disabled
flashing green no alarm, motor enabled
1 green, 3 red over temperature
2 green, 3 red internal voltage out of range
1 green, 4 red power supply voltage too high
2 green, 4 red power supply voltage too low
1 green, 5 red over current / short circuit
1 green, 6 red open motor winding
V+
V
A
B+
B
A+
STEP
DIR
EN
OUT
+
OUT
COM+
920-0059B